互易無耗二端口網(wǎng)絡S參數(shù)測量的一點注記
A NOTE ON THE S-PARAMETER MEASUREMENTS FOR THE RECIPROCAL LOSSLESS TWO-PORT NETWORK
-
摘要: 本文指出互易有耗二端口網(wǎng)絡S參數(shù)的測量方法和數(shù)據(jù)處理方法完全可用于互易無耗二端口網(wǎng)絡中,使這兩種網(wǎng)絡的S參數(shù)測量統(tǒng)一起來。文中給出若干計算和測量實例。Abstract: It is pointed out that methods usually used to measure and process S-parame-ters of reciprocal dissipative two-port networks can be used to any reciprocal lossless two-port networks. Therefore, the method of S-parameter measurement of these two kinds of networkscan be unified. Some examples of calculation and experiment are given.
-
A. Weissfloch, Elektrische Nachrichten Technik u.Elektroakustik, 61(1943)4, 103-106.[2]梁昌洪, 邱長興,電子科學學刊,10(1988)1,1-7.[3]吳宏雄, 徐煒,電子科學學刊,12(1990)5,473- 478.[4]吳宏雄, 楊文超,微波學報,1990年,第1期,第62-66頁.[5]G. A. Deschamps, J. App!. Phys.,24(1953)8, 1046-1050.[6]D. Kajfez, IEEE Trans. on IM, 1M-24 (1975)1, 4-11.[7]梁昌洪,李潤旗,雷振亞,電子學報,18(1990)3,1-6.[8]吳宏雄, 邱熹凡,梁偉雄,微波,1986年,第3期,第1-15頁.[9]周清一, 微波測量技術, 國防工業(yè)出版社, 北京,1964年,76-91頁.[10]張世箕, 測量誤差及數(shù)據(jù)處理, 科學出版社,北京,1979年,265-274頁.[11]吳宏雄, 鄭小健,潘楚華,微波學報,1988年,第3期,第1-8頁.[12]吳宏雄, 電子科學學刊,13(1991)6,561 -567. -
計量
- 文章訪問數(shù): 3264
- HTML全文瀏覽量: 204
- PDF下載量: 930
- 被引次數(shù): 0